Cost-effective medical temperature data logger with built-in sensor

Environment:

  • Indoor
  • Vaccines
  • Fridge
  • Freezer

Measurement:

  • -40 to +85°C

Key Features:

  • USB
  • Splashproof

Product description

The TK-4014-MED monitors temperatures from -40 to +85°C using a built-in sensor. It is a simple, cost-effective solution for accurately recording and verifying storage conditions for pharmaceuticals and vaccines in medical fridges and freezers. The unit is compact and lightweight with a flashing red indicator that can be programmed to indicate if temperatures have deviated from a pre-defined range.

This logger requires Tinytag Explorer software and a USB cable (CAB-0005-USB).

Features

  • Built-in temperature sensor
  • Splash-proof case (IP54)
  • Delayed start option
  • Compact design
  • 16,000 reading capacity
  • High reading resolution
  • User-programmable alarms
  • Low battery monitor
  • User-replaceable battery

Monitoring Vaccines and Pharmaceuticals

The World Health Organisation (WHO) recommendations, on the storage of vaccines and maintenance of the 'cold chain', stipulate that vaccines should be stored and transported according to the manufacturers' recommended temperature range of +2 to +8°C until the point of administration. A small data logger that sits next to the vaccines to monitor temperature provides a straightforward and accurate solution.

Close
Find out more

Tinytag Explorer Software

This is the easy to use Windows program needed to configure the logger and present the data. The Tinytag Explorer software licence allows unlimited users on one site.

Close
Find out more

Calibration Certificates

You have the option of purchasing calibration certificates with our loggers. Standard measurement points are 0 and 30°C for temperature, 20 and 80 % RH (at 25°C) unless specified otherwise. If you don't order calibration, we guarantee the accuracy figures on our datasheets at the point of purchase.

Close
Find out more

Help & Support

Technical support information including FAQs, manuals and documentation for this data logger

View More

Service Calibration

Calibration certificate from

Includes calibration, plus replacement of batteries and seals/desiccant packs (if present)

Book it now