Tinytag Plus 2 - TGP-4500
-25 to +85°C/0 to 100% RH
- Outdoor
- Industrial
- Usb
- Waterproof
Rugged, waterproof temperature and relative humidity logger with built-in sensors
MoreData Loggers
-25 to +85°C/0 to 100% RH
Rugged, waterproof temperature and relative humidity logger with built-in sensors
More-40 to +125°C Requires Thermistor Probe
Temperature data logger with display, for use with a thermistor probe
More-25 to +50°C/0 to 100% RH
Temperature and relative humidity logger with display and built-in sensors
More-40 to +85°C
Rugged, waterproof, temperature data logger with a built-in sensor
More-40 to +125°C Requires Thermistor Probe
Rugged, waterproof, temperature data logger for use with a thermistor probe
More-50 to +300/600°C Requires PT100 Probe
High temperature data logger with display, for use with a PT100 probe
More250V; 0 to 2000A AC
Energy logger kit, with standard size coils (85mm diameter), to monitor single and three phase power supplies
More-30 to +50°C
Temperature data logger with display and built-in sensor
More250V; 0 to 2000A AC
Energy logger kit, with large coils (175mm diameter), to monitor single and three phase power supplies
More-40 to +125°C Requires Thermistor Probe
Rugged, industrial/outdoor, radio temperature data logger for use with a thermistor probe
More-30 to +50°C/-40 to +125°C Requires Thermistor Probe
Temperature logger with display, built-in sensor, and connection for a thermistor probe
More-25 to +85°C / 0 to 100% RH Includes probe
Rugged, waterproof data logger with temperature and relative humidity probe
More250V; 0 to 2000A AC
Energy logger kit, with small tear-drop coils (38mm diameter) to monitor single and three-phase power supplies.
More-25 to +85°C/0 to 100% RH Includes probe
Rugged, industrial/outdoor radio data logger with temperature and relative humidity probe
More-200 to +100°C Requires PT1000 Probe
Low temperature data logger with display, for use with a PT1000 probe
More-25 to +85°C/0 to 100% RH (x2) Includes probe
Rugged, industrial/outdoor radio data logger with two temperature and relative humidity probes
More-40 to +70°C
Submersible temperature data logger with a built-in sensor
More-50 to +300/600°C Requires PT100 Probe
Rugged, waterproof, very high temperature data logger for use with a PT100 probe
More-25 to +50°C/0 to 100% RH
Temperature and relative humidity logger with display and built-in sensors, grey case
More-50 to +300/600°C Requires PT100 Probe
Rugged, industrial/outdoor very high temperature radio data logger for use with a PT100 probe
More-25 to +85°C / 0 to 100% RH Includes probe
Temperature and relative humidity logger with display and accompanying probe
More0 to 14,000 counts
Count input data logger with input lead
More-200 to +250°C Requires PT1000 Probe
Rugged, waterproof, wide range temperature data logger for use with a PT1000 probe
More0 to 20mA
Current data logger with input lead
More-200 to +100°C Requires PT1000 Probe
Rugged, industrial/outdoor very low temperature radio data logger for use with a PT1000 probe
More0 to 25V DC
Voltage data logger with input lead
More0 to 2.5V DC
Voltage data logger with input lead
More-40 to +125°C (x2) Requires Thermistor Probes
Rugged, waterproof temperature data logger for use with two thermistor probes
More-25 to +85°C/0 to 100% RH Includes probe
Temperature and relative humidity logger with display and accompanying probe, grey case
More-40 to +85°C/-40 to +125°C Requires Thermistor Probe
Rugged, waterproof, temperature logger with built-in sensor, and connection for a thermistor probe
More-40 to +125°C (x2) Requires Thermistor Probes
Rugged, industrial/outdoor, radio temperature data logger for use with two thermistor probes
More-30 to +50°C Includes probe
Temperature data logger with display and integral stab probe
More-40 to +125°C (x4) Requires Thermistor Probes
Rugged, industrial/outdoor, radio temperature data logger for use with four thermistor probes
More0 to 2.5 V DC
Voltage data logger with display, and with input lead
More-50 to +300/600°C (x2) Requires PT100 Probes
Rugged, industrial/outdoor very high temperature radio data logger for use with two PT100 probes
More-200 to +100°C (x2) Requires PT1000 Probes
Rugged, industrial/outdoor very low temperature radio data logger for use with two PT1000 probes
More0 to 32,000n
Rugged, industrial/outdoor radio single input count data logger with input lead
More0 to 32,000n (x4)
Rugged, industrial/outdoor radio four input count data logger with input leads
More0.15 to 200A AC
Rugged, data logger with 0 to 200A AC current clamp
More0 to 25V DC
Voltage data logger with display, and with input lead
More0 to 20mA
Current data logger with display, and with input lead.
More0 to 20mA DC
Rugged, industrial/outdoor radio single input current data logger with input lead
More0 to 2.5V DC
Rugged, industrial/outdoor single input voltage radio data logger with input lead
More0.15 to 200A AC
Data logger with display, with 0 to 200A AC current clamp
More0 to 25V DC
Rugged, industrial/outdoor single input voltage radio data logger with input lead
More-30 to +105°C
Waterproof high temperature data logger
More